Induction Furnace Repair Services

Energy-saving intermediate frequency furnace - matters needing attention in maintenance

In induction furnace repair services, the energy-saving intermediate frequency furnace needs attention not only before the furnace is turned on, after the furnace is turned on, but also during maintenance.

The intermediate frequency induction furnace should check the electrical equipment, cooling water system, induction switch air conditioning copper pipe, etc. before starting the furnace.

After the furnace is turned on, when discharging, it is necessary to check the scraps returned to the furnace to prevent infiltration of inflammable and explosive materials and other hazardous materials.

When maintaining the energy-saving intermediate frequency furnace, the high-frequency generator room should be kept clean, and the accumulation of flammable and explosive materials should be prohibited.

After the energy-saving intermediate frequency furnace is ignited, when discharging the material, it is necessary to check the scraps returned to the furnace to prevent the infiltration of inflammable and explosive materials and other hazardous materials.

In order to avoid the occurrence of capping, it is forbidden to add cold material and wet material directly during the desolventization, and it is not allowed to add a large block surface layer after the molten liquid is filled to the upper end.

In order to prevent accidents caused by the explosion of the energy-saving intermediate frequency furnace, the pouring site and the bottom pit in front of the furnace have no water storage and no obstacles;

When pouring, two people should cooperate with each other, and the remaining desolvation can only be poured at the designated place, and it cannot be stolen everywhere.

Hani Metallurgy is a high-tech enterprise specializing in intermediate frequency induction furnaces. For specific energy-saving intermediate frequency furnace wholesales, please consult Hani Metallurgy electric furnace related technical sales personnel.


Hani Metallurgy is the one-stop supplier able to design, manufacture, install, and commission your melt shop and hot rolling mill plant from A to Z.



评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-f...

Induction Furnace Voltage

Induction Furnace Voltage The induced voltage of the intermediate frequency furnace often exists on the inductor coil, the furnace mouth plate, the water-cooled guide rail, and the furnace body bracket. So, what is the reason for the induction voltage of the induction furnace? Next, we will talk about the induced voltage of the intermediate frequency furnace. When the induction coil of the intermediate frequency furnace is working, when an alternating current passes through the coil, an alternating magnetic field is established in the space around the coil. An induced electromotive force is generated in the metal blank in the alternating magnetic field. We often regard the blank as a closed circuit with only one turn of the coil. When the induced electromotive force is generated, an alternating self-circulating circulating current—eddy current is generated in the circuit. Induction heating is to use the heat energy generated by this eddy current to heat the metal blank. The water-cool...

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and ...