跳至主要内容

Induction Furnace Parts Name

Induction Furnace

Induction Furnace Parts Name


Induction furnace is an electric furnace that uses the induction electrothermal effect of materials to heat or melt materials. The main components of an induction furnace include an inductor, a furnace body, a power supply, a capacitor, and a control system.

The main components of an induction furnace include an inductor, a furnace body, a power supply, a capacitor, and a control system.

Under the action of the alternating electromagnetic field in the induction furnace, eddy currents are generated inside the material to achieve the effect of heating or melting. Under the stirring effect of this alternating magnetic field, the composition and temperature of the material in the furnace are relatively uniform, the forging heating temperature can reach 1250°C, and the melting temperature can reach 1650°C.


In addition to heating or smelting in the atmosphere, the induction furnace can also be heated or smelted in vacuum and argon, neon, and other protective atmospheres to meet special quality requirements. Induction furnaces have outstanding advantages in diathermy or melting soft magnetic alloys, high-resistance alloys, platinum group alloys, heat-resistant, corrosion-resistant, wear-resistant alloys, and pure metals.


Induction Furnace Parts Name

Induction furnace parts' names are as followings:

Induction Furnace Shell

Induction furnace induction coil

Induction Furnace Water Cooling Cable

Induction furnace yoke (silicon steel column)

Induction Furnace Hydraulic Furnace Changer Switch: With high current bipolar double-throw water-cooled furnace changer switch is widely used in medium frequency (power frequency) induction furnace

Thyristor (VT), also known as thyristor (SCR): is a high-power semiconductor switching device with many types, including ordinary type, bidirectional type, turn-off type, fast type, and light control type, etc.

24-pulse intermediate frequency power main control board

Fast Melting Cooling Jackets

Induction Furnace Manual Furnace Change Switch: With high current bipolar double-throw water-cooled furnace change switch is widely used in medium frequency (power frequency) induction furnace

Intermediate frequency electric furnace main control board

P-shaped flat-type fast AC fuse

Water-cooled resistors: Water-cooled resistors are resistors that are forced to cool by flowing deionized water (or distilled water).

Yoke shielding copper plate (commonly known as a circuit breaker)

Water-cooled inverter RC absorption board

Plunger hydraulic cylinder: The plunger hydraulic cylinder is a hydraulic actuator that converts hydraulic energy into mechanical energy and performs linear reciprocating motion (or swing motion).

High-strength ejector rod: suitable for 3-60T steel shell furnace

Pulse transformer: The so-called pulse transformer is a broadband transformer.

Intermediate frequency furnace reducer: 231-831 is suitable for 150kg-5 tons intermediate frequency furnace

Stainless steel stronghold: mainly used for sealing hoops of water-cooled cables and cooling pipes

Stainless steel clamps: sealing clamps for water-cooled cables and cooling pipes

Stainless steel ejector rod assembly: suitable for 3-12T aluminum shell furnace


评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-f...

Induction Furnace Voltage

Induction Furnace Voltage The induced voltage of the intermediate frequency furnace often exists on the inductor coil, the furnace mouth plate, the water-cooled guide rail, and the furnace body bracket. So, what is the reason for the induction voltage of the induction furnace? Next, we will talk about the induced voltage of the intermediate frequency furnace. When the induction coil of the intermediate frequency furnace is working, when an alternating current passes through the coil, an alternating magnetic field is established in the space around the coil. An induced electromotive force is generated in the metal blank in the alternating magnetic field. We often regard the blank as a closed circuit with only one turn of the coil. When the induced electromotive force is generated, an alternating self-circulating circulating current—eddy current is generated in the circuit. Induction heating is to use the heat energy generated by this eddy current to heat the metal blank. The water-cool...

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and ...