跳至主要内容

Induction Furnace for Aluminium Melting



Induction Furnace for Aluminium Melting

Induction Furnace for Aluminium Melting


Top 200~1200kg electric aluminum melting induction furnace for casting aluminum melting material, induction electric melting aluminum furnace, electric aluminum induction furnace, aluminum can electric melting induction furnace, electric melting aluminum can furnace.

Advantages of Electric Aluminum Melting Induction Furnace:


1. Save energy and reduce ambient temperature

The original diesel furnace workshop has an auxiliary exhaust pipe for pollution, and a large amount of heat inside and outside the furnace is distributed in the workshop, resulting in high temperatures in the workshop. Therefore, it is in the state of the original furnace, most of which escapes into the air, there is heat conduction loss, the power consumption of production is large, and the production cost is increased. At the same time, the ambient temperature rises. In the electromagnetic induction heating process, the heating element is heated by a magnetic field to reduce the loss of heat conduction, fast heating, and fast melting, thereby reducing energy consumption. Reduce electricity usage. After experimental testing and modified comparison, the power-saving effect is 20%-40%.


2. Rapid heating, accurate and real-time temperature control

The electromagnetic induction heating method is to heat up rapidly through the magnetic field lines, and the aluminum alloy is rapidly melted. Real-time and accurate temperature control improve product quality and production efficiency!


3. Long service life and easy maintenance

The traditional heating method of an electric melting induction furnace is to use resistance wire to heat, and the resistance wire will be oxidized for a long time in a high-temperature environment, which will shorten its service life and cause high maintenance costs. The electromagnetic heating coil is made of insulating material and high-temperature wire, which has a long service life without any maintenance.


4. Power supply

Electromagnetic induction heating With the development and maturity of technology, the production process and technology of components, software, and other reliable protection current power can be 2-200KW.


5. Security


The utility model adopts electromagnetic induction heating, which can reduce the surface temperature of the machine, touch the human body safely, avoid burns and scald accidents caused by traditional heating methods, and ensure production safety. Staff


Features


1 Energy saving and environmental protection, German IGBT power devices, high reliability, stable operation, and low maintenance costs.

2) Digital PLL tracking frequency and automatic load impedance matching.

3 Power supply closed-loop control to avoid temperature changes caused by power failure.

4) Overvoltage, Undervoltage, phase loss, overcurrent, overheat protection, real-time display of parameters, fault diagnosis, and alarm; automatic alarm for leakage, power cut off, and real-time display of working status.

5) PID heating control system, uniform heating temperature, preventing temperature drift of molten aluminum, less burning, uniform metal composition, and improving product qualification rate.

6 (LED) digital temperature controllers, the measurement and control temperature accuracy can reach 3 degrees Celsius, the quality of the aluminum soup is good, the melting temperature is fast, the furnace temperature is easy to control, and the production efficiency is high;

7) The overall structure of polycrystalline mullite fiber in the furnace is small in size, good in insulation performance, low in energy consumption, high in efficiency, and has a long service life when the temperature is above 1200 degrees;

8. Simple operation, the power can be adjusted with the work;

9 (100%) load duration, maximum power, ensure 24 hours of operation.


评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-f...

Induction Furnace Voltage

Induction Furnace Voltage The induced voltage of the intermediate frequency furnace often exists on the inductor coil, the furnace mouth plate, the water-cooled guide rail, and the furnace body bracket. So, what is the reason for the induction voltage of the induction furnace? Next, we will talk about the induced voltage of the intermediate frequency furnace. When the induction coil of the intermediate frequency furnace is working, when an alternating current passes through the coil, an alternating magnetic field is established in the space around the coil. An induced electromotive force is generated in the metal blank in the alternating magnetic field. We often regard the blank as a closed circuit with only one turn of the coil. When the induced electromotive force is generated, an alternating self-circulating circulating current—eddy current is generated in the circuit. Induction heating is to use the heat energy generated by this eddy current to heat the metal blank. The water-cool...

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and ...