跳至主要内容

Advantages of Intermediate Frequency Induction Furnace

Intermediate Frequency Induction Furnace


Advantages of Intermediate Frequency Induction Furnace


1. The intermediate frequency induction furnace can work continuously for 24 hours. Using the principle of electromagnetic induction, the metal material in the alternating magnetic field quickly induces a large eddy current, so that the metal material heats up until the molten metal material is partially or locally or All heat up quickly.


2. The intermediate frequency induction furnace rarely has problems. If there is a problem, 90% is caused by insufficient water pressure or water flow. It is recommended to use an internal circulating water system, which is a closed cooling tower, to cool the intermediate frequency heating furnace, which is economical and cost-effective.


3. The heating cycle of the intermediate frequency induction furnace can be designed according to the productivity. The heating speed is designed according to the heating power, heating temperature and the weight of the heated workpiece. The heating speed can be as fast as 1 second and can be adjusted arbitrarily.


4. The heating range of the intermediate frequency induction furnace is very wide. It can have various heating methods and can heat all kinds of workpieces (replace the detachable induction coil according to the shape of the workpiece), such as end heating and overall heating


5. It is very convenient to replace the inductor of the intermediate frequency induction furnace, that is, the furnace head. The replacement of the inductor can be completed within a few minutes.


6. The operation of the intermediate frequency induction furnace is simple, the power up and down only need to rotate the power knob, the whole operation can learn to start fast in a few minutes, and the heating can be started after water and electricity.


7. The intermediate frequency heating furnace belongs to direct heating, because the internal heating of the metal is different from heating, and there is no heat loss of radiant conduction heating, so it consumes less electricity, less heat loss, less than friction, and less energy consumption than other similar products.


8. Intermediate frequency induction furnace has good heating performance, good heating uniformity and high overall effect. The heating of the intermediate frequency electric furnace is very uniform (you can also adjust the density of the induction coil, so that each part of the workpiece can obtain the required temperature waste.


9. The intermediate frequency induction furnace has a variety of protection functions, reducing use failures and adjustable power. Infinitely adjustable output power protection: with alarm indications such as overvoltage, overcurrent, overheating, water shortage, etc., and automatic control and protection


10. The intermediate frequency induction furnace is safe and reliable, with over-voltage, over-current, over-heating, water shortage and other alarm indications, and automatic control and protection. No high voltage, safe operation for workers.


Induction furnace power system



induction furnace for sale


评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-f...

Induction Furnace Voltage

Induction Furnace Voltage The induced voltage of the intermediate frequency furnace often exists on the inductor coil, the furnace mouth plate, the water-cooled guide rail, and the furnace body bracket. So, what is the reason for the induction voltage of the induction furnace? Next, we will talk about the induced voltage of the intermediate frequency furnace. When the induction coil of the intermediate frequency furnace is working, when an alternating current passes through the coil, an alternating magnetic field is established in the space around the coil. An induced electromotive force is generated in the metal blank in the alternating magnetic field. We often regard the blank as a closed circuit with only one turn of the coil. When the induced electromotive force is generated, an alternating self-circulating circulating current—eddy current is generated in the circuit. Induction heating is to use the heat energy generated by this eddy current to heat the metal blank. The water-cool...

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and ...