How to Operate an Induction Furnace?

 
Induction Furnace

How to Operate an Induction Furnace?


Furnace Inspection

1. Check for cold cracks in the furnace body. Cracks below 2 mm are not used for repair. Cracks exceeding two milli-meters must be repaired.

2. Pay special attention to horizontal cracks because horizontal cracks are difficult to bridge when starting the furnace. 1.3 Frequently check the melting loss of the furnace body, and the inspection method must be accurate.

Cold Furnace Open

Heating curve; 200-300 degrees per hour in the beginning; when the temperature reaches 900-1000 degrees; work according to the normal operating process.

Hot Furnace Shutdown

After pouring the molten iron, clean up the slag, put in the molten iron block, heat it until the molten block is red, cover the furnace cover, and let the furnace body cool down slowly. Remember not to use compressed air to cool the furnace body rapidly.

Operation Matters

1. Pay attention to prevent mechanical damage to the furnace mouth when adding the charge.

2. The slag in the furnace should be cleaned as much as possible, because the slag is particularly eroded to the furnace body, and there are many harmful chemical components in the slag, which can easily cause abnormal melting loss locally.

3. When adding the molten iron after desulfurization, the slag must be removed. Prevent the alkaline chemicals in the molten iron from entering the intermediate frequency furnace through the molten iron transfer package. 

Once it enters the furnace body, it will chemically react with the refractory material in the furnace body, and the furnace body refractory material will produce abnormal melting and erosion.

4. When the use temperature does not reach the use temperature of the selected refractory material, the temperature of the molten iron in the furnace should be increased 1-2 times a week to the use temperature of the refractory material.

5. When the alloy is added, its solid size is not more than 30 mm to prevent the alloy from sinking to the bottom and dissolving and damaging the refractory at the bottom of the furnace body after it reacts with the molten iron.

6. Pay attention to iron oxide in molten iron daily. 

If necessary, add metallurgical grade carbonized ferrosilicon to reduce iron trioxide in the molten iron. However, the temperature of adding ferrosilicon should be controlled at 1350-1400 degrees for 15-25 minutes, which is beneficial The ferrosilicon melts. 4.7 When pouring molten iron, the power supply of the furnace body must be turned off to prevent the molten iron at the bottom of the furnace from overheating.



induction furnace for sale



induction melting furnace


评论

此博客中的热门博文

Application Range of Medium Frequency Induction Furnace

  Application Range of Medium Frequency Induction Furnace (1) Intermediate frequency induction furnace is used for forging and rolling 1. Wheel forgings, ring forgings, shaft forgings, cylinder forgings, gear forgings, stainless steel forgings, and large flanges. 2. Hot heading of standard parts and fasteners, such as heating for tempering, forging, and extrusion of high tools. 4. Quenching and tempering of bar materials (2) Intermediate frequency induction furnaces are used for smelting   Including the smelting of steel, gold, silver, copper, and aluminum, especially in the foundry industry (3) Intermediate frequency induction furnace is used for heat treatment 1. Heat treatment of various hardware tools and hand tools. Such as pliers, wrenches, screwdrivers, hammers, axes, etc. 2. High-frequency hardened crank pins, sprockets, camshafts, valves, various rocker arms, rocker shafts for various auto parts and motorcycle parts; various gears, spline shafts, transmission axles, High-f...

Induction Furnace Voltage

Induction Furnace Voltage The induced voltage of the intermediate frequency furnace often exists on the inductor coil, the furnace mouth plate, the water-cooled guide rail, and the furnace body bracket. So, what is the reason for the induction voltage of the induction furnace? Next, we will talk about the induced voltage of the intermediate frequency furnace. When the induction coil of the intermediate frequency furnace is working, when an alternating current passes through the coil, an alternating magnetic field is established in the space around the coil. An induced electromotive force is generated in the metal blank in the alternating magnetic field. We often regard the blank as a closed circuit with only one turn of the coil. When the induced electromotive force is generated, an alternating self-circulating circulating current—eddy current is generated in the circuit. Induction heating is to use the heat energy generated by this eddy current to heat the metal blank. The water-cool...

Troubleshooting of Medium Frequency Furnace

Troubleshooting of Medium Frequency Furnace This article introduces the faults and solutions of medium frequency furnace. 1. Fault phenomenon: large DC current, low DC voltage, and if the voltage, dull equipment sound, over-current protection. Analysis and treatment: the thyristor with one arm of the inverter bridge may be short-circuited or open-circuited, resulting in the operation of the three-arm inverter bridge. Use an oscilloscope to observe the voltage drop waveform of the thyristor on the four bridge arms of the inverter bridge. If the voltage drop waveform of the thyristor on one bridge arm is a line, the thyristor has been through; if it is a sine wave, the thyristor has not been through. Replace the through thyristor; find out the reason why the thyristor is not turned on. 2. Fault phenomenon: when the heavy load cold furnace is started, all electrical parameters and sounds are normal, but the power cannot be raised, and overcurrent protection. Analysis and ...